Blueskin® VP100

Self-adhered water resistive air barrier membrane

Blueskin® VP100

Self-Adhered Water Resistive Air Barrier Membrane

Blueskin® VP100 is a premium, self-adhered vapor permeable, water-resistive barrier designed for wood-framed residential and multi-family construction. It protects buildings by eliminating air gaps and water and moisture intrusion and self-sealing around nails and fasteners. Blueskin VP100 combines an engineered film and a patented, permeable adhesive technology with split-back poly-release film.

When used as part of the Henry® 1-2-3 Moisture Control System™, Blueskin VP100 is backed by an industry-leading 15-year warranty. Repairs are covered for both materials and labor with a single point of contact.

Features

  • Self-seals around nails and fasteners for lasting water tightness
  • Achieves more than 95% drainage efficiency
  • Eliminates uncontrolled air leakage to reduce energy costs
  • Improves air quality by helping to reduce mold proliferation
  • Easy installation with peel-and-stick system

Packaging

  • Roll length: 100ft
  • Roll widths: 4”, 6”, 9”, 12”, and 48”

Related products to qualify for the 15 year warranty

Literature

  • Data Sheets

    Blueskin® VP100 Product Data Sheet Click to download  

    Blueskin® VP100 Technical Data Sheet Click to download  

    Blueskin® VP100 SDS Sheet Click to download  

    Blueskin® VP100 Accessory Products Data Sheet Click to download  

    ICC-ES Evaluation Report Click to download  

  • Installation Guides

    Blueskin® VP100 Installation Manual Click to download

  • Specifications

    Blueskin VP100 Self Adhered WRB Section Guide Spec Click to download  

    Tech Talk Declare Label VP100 Read List Free Click to download  

  • Architectural Details

    VPWRB-1A Wall Foundation Slab Below Grade pdf cad

    VPWRB-1B Wall Foundation Slab on Grade pdf cad

    VPWRB-1C Wall Foundation Transition No Brick Ledge pdf cad

    VPWRB-2A Pipe Penetration 0.5 Inch Wide Gap Max pdf cad

    VPWRB-2B Pipe Penetration 0.75 Inch Wide Gap Max pdf cad

    VPWRB-3A Inside and Outside Corners at Sheathing pdf cad

    VPWRB-3B Inside and Outside Corners at CMU pdf cad

    VPWRB-3C Inside and Outside Corners at Soffit pdf cad

    VPWRB-4A Substrate Transition pdf cad

    VPWRB-4B Substrate Transition pdf cad

    VPWRB-5A Thru-Wall Flashing pdf cad

    VPWRB-6A-F1 Flanged Window Section Method A1 - Fortiflex Butyl pdf cad

    VPWRB-6A-F2 Flanged Window Sequence Installation Method A - Fortiflex Butyl pdf cad

    VPWRB-6A-L1 Flanged Window Section Method A - Low wind and water exposure pdf cad

    VPWRB-6A-L2 Flanged Window Sequence Installation Method A - Low wind and water exposure pdf cad

    VPWRB-6A-P2 Flanged Window Sequence Installation Method A - Pan flashing at sill pdf cad

    VPWRB-6A-P1 Flanged Window Section Method A - Pan flashing at sill pdf cad

    VPWRB-6A1-F1 Flanged Window Section Method A1 - Fortiflex Butyl pdf cad

    VPWRB-6A1-F2 Flanged Window Sequence Installation Method A1 - Fortiflex Butyl pdf cad

    VPWRB-6A1-L1 Flanged Window Section Method A1 - Low wind and water exposure pdf cad

    VPWRB-6A1-L2 Flanged Window Sequence Installation Method A1 - Low wind and water exposure pdf cad

    VPWRB-6A1-P2 Flanged Window Sequence Installation Method A1 - Pan flashing at sill pdf cad

    VPWRB-6B-P1 Flanged Window Section Method B - Pan flashing at sill pdf cad

    VPWRB-6B-L1 Flanged Window Section Method B - Low wind and water exposure pdf cad

    VPWRB-6B-L2 Flanged Window Sequence Installation Method B - Low wind and water exposure pdf cad

    VPWRB-6B1-P1 Flanged Window Section Method B1 - Pan flashing at sill pdf cad

    VPWRB-6B-P2 Flanged Window Sequence Installation Method B - Pan flashing at sill pdf cad

    VPWRB-6B1-L1 Flanged Window Section Method B1 - Low wind and water exposure pdf cad

    VPWRB-6B1-L2 Flanged Window Sequence Installation Method B1 - Low wind and water exposure pdf cad

    VPWRB-6B1-P2 Flanged Window Sequence Installation Method B - Pan flashing at sill pdf cad

    VPWRB-6C Hollow Metal Door pdf cad

    VPWRB-7A Reverse Lap pdf cad

    VPWRB-8A Construction Joints 0.5 Inch Gap Max pdf cad

    VPWRB-8B Construction Joints 1 Inch Gap Max pdf cad

    VPWRB-8C Construction Joints 2 Inch Gap Max pdf cad

    VPWRB-8D Deflection Joint pdf cad

    VPWRB-9A Air Barrier Transition at sloped roof pdf cad

    VPWRB-9B Roofing Wrapping Parapet pdf cad

    VPWRB-9C Air Barrier Transition at Parapet pdf cad

  • Warranties

    15 Year Warranty Click to download

    Standard Warranty Click to download

  • LEED Declarations

    BlueskinVP LEED Declarations Click to download

    Blueskin Weather Barrier LEED Declarations Click to download

  • Health Product Declarations

    Blueskin® VP100 Health Product Declaration Click to download

    Declare Blueskin® VP100 Label Click to download

  • Tech-Talks

    Henry® Blueskin® VP100 Self-Adhered Water Resistive Air Barrier Earns Red List Free Status Click to download

    Fastener penetrations through air barrier membranes Click to download

    Blueskin® VP Cold Weather Application Click to download

    Henry® Blueskin® VP100 helps homes meet 2012, 2015 and 2018 IECC Code Changes Click to download

    Henry® Living Building Challenge Red List Click to download

  • Videos

Complete the form below to request a FREE sample!