CCW 705
CCW 705
Self-Adhered Air, Vapor and Water Resistive Barrier
CCW-705 is a self-adhered, water-resistive air barrier consisting of an SBS rubberized asphalt compound, which is integrally laminated to a blue cross-laminated HPDE film. It is specifically designed to be self-adhered to a prepared substrate providing an air, vapor and water resistive barrier in full wall applications or as penetration/flashing membrane with other air barrier systems.
Sizes Available:
4"
x100'
6"
x100'
9"
x100'
12"
x100'
18"
x100'
24"
x100'
36"
x100'
36"
x 75'
Product Details
CCW-705 is designed for use as a self-adhered air, vapor and water resistive barrier in above-grade walls. It can also be used as a transition sheet in conjunction with Henry® Air-Bloc® and Barritech™ fluid applied air barriers in details such as rough openings, angle changes, joints, transitions and terminations. CCW-705 can also be used as a self-adhered flashing for providing an air and watertight seal around openings, over joints, over transitions and at terminations in wall assemblies. The product is installed to fully supported, opaque wall substrates and covered with a code-approved exterior cladding or thermal barrier.
- Factory-controlled composition and thicknes
- Impermeable to air, moisture vapor and water
- Compatible in Henry® Air-Bloc® 17MR, 16MR, 21FR, 21 and Barritech VP, NP, NP LT fluid applied air barrier assemblies
Codes & Approvals
- International Energy Conservation Code “IECC” 2021 Section C402 Air barrier material <0.004 CFM/ft2 @ 1.57PSF (0.02 L/[s*m2]@ 75Pa) per ASTM E2178 and air barrier assembly <0.04 CFM/ft2 @ 1.57PSF (0.2 L/[s*m2]@ 75Pa) per ASTM E2357
- International Building Code “IBC” 2021 Section 1403.2 Water resistive barrier: Self-adhered sheet, ICC-ES AC-38/ AAMA 711, non-permeable; must not be used where Grade D “permeable” product is required. Section 1404.4 Flashing per AAMA 711.
- Air Barrier Association of America: Evaluated air barrier material and air barrier assembly
- USGBC LEED v4: MR Credit Building Product Disclosure & Optimization; EPD 10573 product-specific environmental product declaration “EPD” with Cradle to Gate Scope
-
Simple peel and stick application
-
Provided in convenient sizes for covering the whole wall or for flashing details
-
Strong adhesion to many substrates prepared with Henry® adhesive/primer
-
Flexible at low temperatures
-
Self-gasketing when penetrated and under compression with self-tapping screws
Technical & Installation
-
CCW-705 & CCW-705 XLT | Guide Specification
Download
-
CCW-705 & CCW-705 XLT Architectural Details COMBINED - PDF
Download
-
CCW-705 & CCW-705 XLT Architectural Details COMBINED - CAD
Download
-
705-0A.1 CCW-705 Detail Index
Download
-
705-0A.1 System Components
Download
-
705-0B.1 Typical Assemblies, Exterior Walls
Download
-
705-1A.1 Installation - Sheathing
Download
-
705-1A.2 Installation - Sheathing
Download
-
705-1B.2 Installation - Masonry
Download
-
705-2B.1 Transition - Self-Adhered Flashing
Download
-
705-2B.2 Transition - Self-Adhered Flashing
Download
-
705-3A.1 Sheathing Joints
Download
-
705-3B.1 Masonry Joints
Download
-
705-3C.1 Precast Concrete Panel Joints
Download
-
705-4A.1 Control Joints - Sheathing
Download
-
705-4B.1 Control Joints - Masonry
Download
-
705-4C.1 Expansion Joints - Above Grade Walls
Download
-
705-4C.2 Expansion Joints - Above Grade Walls
Download
-
705-5A.1 Non-Flanged Windows, Self-Adhered Flashing Before WRD
Download
-
705-5A.2 Non-Flanged Windows, Self-Adhered Flashing After WRD
Download
-
705-5B.1 Flanged Windows, Self-Adhered Flashing Before WRD
Download
-
705-5B.2 Flanged Windows, Self-Adhered Flashing After WRD
Download
-
705-5R.1 Doors, Jamb Flashing
Download
-
705-6A.1 Cladding Attachment, Masonry Anchors - Sheathing
Download
-
705-6A.2 Cladding Attachment, Masonry Anchors - Sheathing
Download
-
705-6B.2 Cladding Attachment, Masonry Anchors - Masonry
Download
-
705-6C.1 Cladding Attachment, Furring and Girts
Download
-
705-6D.1 Insulation Attachment
Download
-
705-6E.1 Head Flashing - Masonry
Download
-
705-6E.2 Head Flashing - Drip Edge
Download
-
705-7A.1 Shelf Angle - Continuous at Floor Line
Download
-
705-7B.1 Shelf Angle - Thermal Break
Download
-
705-7C.1 Knife Plate
Download
-
705-9A.1 Transition., CMU to Steel Column
Download
-
705-9B.1 Transition, Stud Wall to Concrete
Download
-
705-9C.1 Transition., CMU to Concrete
Download
-
705-9D.1 Transition., CMU to stud Wall
Download
-
705-10A.1 Inside & Outside Corners, Self-Adhered Flashing - Sheathing
Download
-
705-10C.1 Inside & Outside Corners, CMU Substrates
Download
-
705-11A.1 Pipe Penetration - Liquid-Applied Flashing
Download
-
705-12A.2 Decks, Upturn at Deck to Wall
Download
-
705-12C.1 Balconies, Upturn at Deck to Wall
Download
-
705-13A.1 Roofing Parapet, Option #1
Download
-
705-13A.2 Roofing Parapet, Option #2
Download
-
705-13B.1 Roofing Drip Edge
Download
-
705-14A.1 Slab to Wall, Below Grade with Masonry Ledge
Download
-
705-14B.1 Slab to Wall, At Grade with Masonry Ledge
Download
-
705-14C.1 Slab to Wall, No Masonry Ledge, Option #1
Download
-
705-14D.1 Slab to Wall, No Masonry Ledge, Option #2
Download
Sustainability
-
CCW-705 & CCW-705 XLT | LEED Certification
Download